Plant assets

Plant · updated 2026-08-07 · 134 assets

Scores 134

Tag Name Tier Consequence Status Probability Risk Scored
AC-2 AC-2 1 5 CONFIRMED — — 2026-10-24
AHU-1 AHU-1 1 5 CONFIRMED — — 2026-10-24
AHU-1-DRV Drive & belts 1 5 PROVISIONAL — — 2026-10-24
AHU-1-MTR Supply motor 1 5 PROVISIONAL — — 2026-10-24
AHU-1-OA OA damper 1 5 PROVISIONAL — — 2026-10-24
AHU-1-SF Supply fan (blower) 1 5 PROVISIONAL — — 2026-10-24
AHU-2 AHU-2 1 5 CONFIRMED — — 2026-10-24
AHU-2-DRV Drive & belts 1 5 PROVISIONAL — — 2026-10-24
AHU-2-MTR Supply motor 1 5 PROVISIONAL — — 2026-10-24
AHU-2-OA OA damper 1 5 PROVISIONAL — — 2026-10-24
AHU-2-SF Supply fan (blower) 1 5 PROVISIONAL — — 2026-10-24
AHU1-VFD Supply-fan VFD 1 5 PROVISIONAL — — 2026-10-24
AHU2-VFD Supply-fan VFD 1 5 PROVISIONAL — — 2026-10-24
BMS Building management (Honeywell EBI) 1 5 CONFIRMED — — 2026-10-24
CT Cooling tower 1 5 CONFIRMED — — 2026-10-24
DWB Domestic city water booster 1 5 CONFIRMED — — 2026-10-24
FW Feedwater tank (deaerator) 1 5 CONFIRMED — — 2026-10-24
RTU-1 RTU-1 (HVAC-1) 1 5 CONFIRMED — — 2026-10-24
AC-1 Air compressor 1 2 4 CONFIRMED — — 2026-10-24
AC-2-CA Air compressor 2 2 4 CONFIRMED — — 2026-10-24
B-1 Boiler #1 1 4 CONFIRMED — — 2026-10-24
B-2 Boiler #2 1 4 CONFIRMED — — 2026-10-24
CH-1 Chiller #1 1 4 CONFIRMED — — 2026-10-24
CH-2 Chiller #2 1 4 CONFIRMED — — 2026-10-24
E-25 E-25 1 4 CONFIRMED — — 2026-10-24
E-39 E-39 1 4 CONFIRMED — — 2026-10-24
E-44 E-44 1 4 CONFIRMED — — 2026-10-24
E-45 E-45 1 4 CONFIRMED — — 2026-10-24
E-5 E-5 1 4 CONFIRMED — — 2026-10-24
FWP-1 Feedwater pump 1 1 4 CONFIRMED — — 2026-10-24
FWP-2 Feedwater pump 2 1 4 CONFIRMED — — 2026-10-24
HV-4 HV-4 (H&V-4) 1 4 CONFIRMED — — 2026-10-24
ICE-1 Ice machine 3 4 CONFIRMED — — 2026-10-24
P-5 Condenser pump 5 2 4 CONFIRMED — — 2026-10-24
P-5A Condenser pump 5A 2 4 CONFIRMED — — 2026-10-24
P-6 CHW pump 6 2 4 CONFIRMED — — 2026-10-24
P-6A CHW pump 6A 2 4 CONFIRMED — — 2026-10-24
AC1-AHU1-VFD VFD enclosure AC (AC1) 2 3 PROVISIONAL — — 2026-10-24
AC2-AHU2-VFD VFD enclosure AC (AC2) 2 3 PROVISIONAL — — 2026-10-24
AHU-1-BMS Sensors & BMS points 2 3 PROVISIONAL — — 2026-10-24
AHU-1-CC-BANK Cooling coil bank (totals) 2 3 PROVISIONAL — — 2026-10-24
AHU-1-CC1 Cooling coil A (CC-1) 2 3 PROVISIONAL — — 2026-10-24
AHU-1-CC2 Cooling coil B (CC-2) 2 3 PROVISIONAL — — 2026-10-24
AHU-1-CC3 Cooling coil C (CC-3) 2 3 PROVISIONAL — — 2026-10-24
AHU-1-FLT Filters 2 3 PROVISIONAL — — 2026-10-24
AHU-1-HTG HHW heating coil 2 3 PROVISIONAL — — 2026-10-24
AHU-1-RA RA damper 2 3 PROVISIONAL — — 2026-10-24
AHU-2-BMS Sensors & BMS points 2 3 PROVISIONAL — — 2026-10-24
AHU-2-CC-BANK Cooling coil bank (totals) 2 3 PROVISIONAL — — 2026-10-24
AHU-2-CC1 Cooling coil A (CC-1) 2 3 PROVISIONAL — — 2026-10-24
AHU-2-CC2 Cooling coil B (CC-2) 2 3 PROVISIONAL — — 2026-10-24
AHU-2-CC3 Cooling coil C (CC-3) 2 3 PROVISIONAL — — 2026-10-24
AHU-2-FLT Filters 2 3 PROVISIONAL — — 2026-10-24
AHU-2-HTG HHW heating coil 2 3 PROVISIONAL — — 2026-10-24
AHU-2-RA RA damper 2 3 PROVISIONAL — — 2026-10-24
AR-1 Compressed air receiver 2 3 CONFIRMED — — 2026-10-24
DHW Domestic water heater 2 3 CONFIRMED — — 2026-10-24
DRY-E East air dryer station 3 3 CONFIRMED — — 2026-10-24
DRY-W West air dryer 3 3 CONFIRMED — — 2026-10-24
E-1 E-1 2 3 CONFIRMED — — 2026-10-24
E-11 E-11 2 3 CONFIRMED — — 2026-10-24
E-12 E-12 2 3 CONFIRMED — — 2026-10-24
E-13 E-13 2 3 CONFIRMED — — 2026-10-24
E-14 E-14 2 3 CONFIRMED — — 2026-10-24
E-15 E-15 2 3 CONFIRMED — — 2026-10-24
E-16 E-16 2 3 CONFIRMED — — 2026-10-24
E-17 E-17 2 3 CONFIRMED — — 2026-10-24
E-18 E-18 2 3 CONFIRMED — — 2026-10-24
E-19 E-19 2 3 CONFIRMED — — 2026-10-24
E-2 E-2 2 3 CONFIRMED — — 2026-10-24
E-20 E-20 2 3 CONFIRMED — — 2026-10-24
E-21 E-21 2 3 CONFIRMED — — 2026-10-24
E-22 E-22 2 3 CONFIRMED — — 2026-10-24
E-23 E-23 2 3 CONFIRMED — — 2026-10-24
E-24 E-24 2 3 CONFIRMED — — 2026-10-24
E-26 E-26 2 3 CONFIRMED — — 2026-10-24
E-27 E-27 2 3 CONFIRMED — — 2026-10-24
E-28 E-28 2 3 CONFIRMED — — 2026-10-24
E-29 E-29 2 3 CONFIRMED — — 2026-10-24
E-3 E-3 2 3 CONFIRMED — — 2026-10-24
E-30 E-30 2 3 CONFIRMED — — 2026-10-24
E-32 E-32 2 3 CONFIRMED — — 2026-10-24
E-33 E-33 2 3 CONFIRMED — — 2026-10-24
E-34 E-34 2 3 CONFIRMED — — 2026-10-24
E-36 E-36 2 3 CONFIRMED — — 2026-10-24
E-37 E-37 2 3 CONFIRMED — — 2026-10-24
E-38 E-38 2 3 CONFIRMED — — 2026-10-24
E-40 E-40 2 3 CONFIRMED — — 2026-10-24
E-41 E-41 2 3 CONFIRMED — — 2026-10-24
E-46 E-46 2 3 CONFIRMED — — 2026-10-24
E-47 E-47 2 3 CONFIRMED — — 2026-10-24
E-48 E-48 2 3 CONFIRMED — — 2026-10-24
E-50A E-50A 2 3 CONFIRMED — — 2026-10-24
E-50B E-50B 2 3 CONFIRMED — — 2026-10-24
E-6 E-6 2 3 CONFIRMED — — 2026-10-24
REF-1 REF-1 2 3 CONFIRMED — — 2026-10-24
REF-11 REF-11 2 3 CONFIRMED — — 2026-10-24
REF-14 REF-14 2 3 CONFIRMED — — 2026-10-24
REF-3 REF-3 2 3 CONFIRMED — — 2026-10-24
REF-5 REF-5 2 3 CONFIRMED — — 2026-10-24
REF-6 REF-6 2 3 CONFIRMED — — 2026-10-24
REF-7 REF-7 2 3 CONFIRMED — — 2026-10-24
REF-8 REF-8 2 3 CONFIRMED — — 2026-10-24
REF-9 REF-9 2 3 CONFIRMED — — 2026-10-24
USG Cemline unfired steam generator 3 3 CONFIRMED — — 2026-10-24
VP-1 Vacuum pump 1 2 3 CONFIRMED — — 2026-10-24
VP-2 Vacuum pump 2 2 3 CONFIRMED — — 2026-10-24
AHU-1-HUM Humidification 3 2 PROVISIONAL — — 2026-10-24
AHU-1-MA Mixed-air section 3 2 PROVISIONAL — — 2026-10-24
AHU-2-HUM Humidification 3 2 PROVISIONAL — — 2026-10-24
AHU-2-MA Mixed-air section 3 2 PROVISIONAL — — 2026-10-24
CP-1 Duplex condensate pump/motor #1 2 2 CONFIRMED — — 2026-10-24
CP-2 Duplex condensate pump/motor #2 2 2 CONFIRMED — — 2026-10-24
HX-1 HHW heat exchanger Hx1 2 2 CONFIRMED — — 2026-10-24
HX-2 HHW heat exchanger Hx2 2 2 CONFIRMED — — 2026-10-24
P-3 Reheat HX pump 3 2 2 CONFIRMED — — 2026-10-24
P-3A Reheat HX pump 3A 2 2 CONFIRMED — — 2026-10-24
QT-1 Boiler bottom-blow quench tank 2 2 CONFIRMED — — 2026-10-24
E-31 E-31 2 1 PROVISIONAL — — 2026-10-24
E-35 E-35 2 1 PROVISIONAL — — 2026-10-24
E-4 E-4 2 1 CONFIRMED — — 2026-10-25
E-49 E-49 2 1 CONFIRMED — — 2026-10-25
E-51 E-51 2 1 CONFIRMED — — 2026-10-25
E-9 E-9 2 1 CONFIRMED — — 2026-10-25
REF-12 REF-12 2 1 CONFIRMED — — 2026-10-25
REF-13 REF-13 2 1 PROVISIONAL — — 2026-10-24
REF-2 REF-2 2 1 CONFIRMED — — 2026-10-25
AIR Air side — — — — — —
BUILDING Building — — — — — —
CA Compressed air — — — — — —
CHW Chilled-water plant — — — — — —
EXH Exhaust & roof fans — — — — — —
H2O Water systems & meters — — — — — —
STM Steam & heating plant — — — — — —

CH-1 · chiller

Chiller #1

Trane Agility HDWA300 — 250 ton VFD centrifugal, R-513A. .

Tier
1
Consequence
4 CONFIRMED
Probability
—
Risk
—
Scored
2026-10-24
Consequence note
CH-2. Seasonal backup: 2nd chiller only needed at outside-air enthalpy of 31.5 h or higher; losing one does not take the system off line but hits the indoor environment hard, so 4 (Tier 1 floor).

Identity

Plant tag
Chiller #1
Mfr model
HDWA300
Type
Centrifugal, 460 V VFD (Trane Agility)
Serial No.
L20A00538
S.O. No.
MLQ180A
AED model
AFT0359FAAA00C2B1
AED part No.
45369360008
Date of mfg
11-05-20
Product description
ETON 250 (250 tons)

Nameplate (unit)

Nameplate voltage
460 V, 3ø 60 Hz
Nameplate kW
139 kW
RLA
185 A
Line current range
414–506 VAC
MCA
230 A
Max overcurrent protective device
400 A
Short circuit current rating
65,000 A
Compressor motor
460 V, 3ø, 60 Hz, VFD — 139 kW / 185 A RLA
Control circuit
115 V AC / 60 Hz / 3000 VA max (CPT)
Factory charge
525 lb of R-513A
Max refrigerant working pressure
HI side 300 psig · LO side 200 psig
Factory test pressure
HI side 330 psig · LO side 260 psig

Field calibration (kW vs RLA%)

Point
106.9 kW @ 69% RLA
Fit
Linear through origin until 2nd point added

Hydronics (plant defaults)

CHW design flow (dashboard default)
597.4 GPM
Cond design flow (dashboard default)
750 GPM
CHW design temps (twin sheet)
55 → 45°F typical selection

Refrigerant

Type
R-513A
Charge
525 lb (factory, nameplate)

Children